Novo 10 Liter Oxygen Generator; How to use it and the main disadvantages

by time news

Nuvo 10 Oxygen Concentrator

Novo 10L Oxygen Generator is used to provide continuous oxygen-rich air to patients with low blood oxygen level, and it is a portable device that can be carried anywhere.

Table of contents

The Nuvo 10 Oxygen Concentrator, or Nuvo 10 Oxygen Concentrator, is a device that is used as a means of providing continuous oxygen-rich air to adolescent or elderly patients with health conditions that result in low blood oxygen levels ( hypoxia).


Here are the most important specifications of the device:

average oxygen contentMore than 90% at a rate of 2 liters/min

87 – 95.5% at a rate of 10 liters / minute

flow rate2 – 10 liters per minute
the pressure20 Psi
noise levelLess than 58 dB
pipeAluminum, PVC, copper, polyurethane, silicon
Oxygen outletcopper
capacitorpolypropylene
filterPolypropylene, polyester
operating conditionsTemperature: 10 – 40 ° C

Humidity: 15 – 95%

Max altitude: 1500m

Storage conditionsTemperature: -20 – 60°C

Humidity: 15 – 95%

Dimensions39.4 * 39.6 * 70.6 cm
weight26 kg approx

How the Novo 10 Liter Oxygen Generator Works

How the Novo 10 Liter Oxygen Generator Works with a Humidifier
How the Novo 10 Liter Oxygen Generator Works

The Novo 10L Oxygen Generator starts its work by drawing air into the air inlet filter, this filtered air enters the compressor through a fine filter, then the compressed air comes out of the compressor and passes through a heat exchanger, which reduces the temperature of the compressed air, and then, the electronic valve system directs Air to one of the two tubes containing a molecular sieve absorbs nitrogen from the air as it is forced through the layers of the sieve. This process is called pressure swing absorption (PSA).

After passing through the regulator the rate of the produced gas delivered to the patient is adjusted by the flowmeter adjusting valve, and finally, it passes through a fine particulate filter and then over a sensor that detects the concentration of oxygen before it exits the device through a fireproof port, the gas produced is delivered to the patient It is absorbed by the tissues inside the nose and lungs.

See: Biolite M860″ Vital Signs Meter


How to use the Novo 10 Liter Oxygen Generator

Hand adjusts the flow spool to show how to use the Novo 10L Oxygen Generator
How to use the Novo 10 Liter Oxygen Generator

Here are the correct steps to use for the Novo 10L Oxygen Generator:

  1. If the machine is used with a humidifier, connect the oxygen outlet to the humidifier nozzle, and make sure all parts are connected correctly to avoid leakage.
  2. When not using a humidifier, connect the oxygen outlet directly to the breathing mask.
  3. Plug the power cable into a power outlet of the correct voltage and frequency as specified by the manufacturer.
  4. Press the power button, set the Flow Adjustment Roller to the appropriate value (as shown in the image above), and adjust the respirator to fit your face.
  5. At the end of the treatment session, press the power button to turn off the device, the flow of oxygen-enriched air continues for about a minute after the device is turned off.
  6. After turning off the device, you should wait 3-5 minutes before turning it back on again, the system pressure should dissipate properly before restarting the device.

Also Read: Home Sleep Test


Important instructions and precautions when using the Novo 10 Liter Oxygen Concentrator

White Nuvo 10 Oxygen Generator
Nuvo 10 . Oxygen Generator

There are some important warnings to be aware of before using the Novo 10 Liter Oxygen Generator, and they are:

  • This device is not for life support, any patient who is unable to express discomfort while using this device, whether they are the elderly, children, or any other patient should be subject to additional monitoring.
  • This device supplies highly concentrated oxygen that promotes rapid combustion. No smoking or open flames are allowed in the same room as the device, in order to avoid severe fire, bodily injury or death.
  • Oxygen aids the combustion of flammable materials. Do not use oil, grease, petroleum products, petroleum-based cosmetics or other flammable products while the appliance is operating.
  • Only trained persons should be allowed to operate the device.
  • Warning against continuing to smoke, due to the increased risk of fire, and the possibility that a poor diagnosis as a result of smoking may lead to a loss of treatment benefit.
  • To ensure your safety, use the device only after selecting the settings described based on your specific activity levels, and use only the accessories that were used when making your settings.
  • If you feel uncomfortable or experience a medical emergency while undergoing oxygen therapy, seek medical help immediately.
  • The device is equipped with an audible alarm to warn the user when problems occur, the maximum distance that the user can move away from in order to hear the alarm in proportion to the level of ambient noise.
  • The device must be stored in a dry environment, and it must be stored, transported and used in the vertical position only.
  • Oxygen concentration can be affected after long storage periods, check the device before use.
  • Avoid entangling the breathing tube around the patient’s neck to avoid the risk of injury or suffocation.
  • Prolonged use of the breathing mask may cause irritation to the ears, nose and neck pain, and for comfort, only water-based lubricants are recommended.
  • The nasal passages may become irritated after prolonged exposure to oxygen gas. Consult your physician about the use of a humidifier during treatment.
  • The Novo 10L Oxygen Generator must be kept away from heat sources, incandescent sources, etc., to avoid the risk of fire or explosion.
  • The appliance must be operated in a well-ventilated area, free from contaminants and fumes, and must be located in a place where the location and storage of the mains cable and oxygen tubes do not present a tripping hazard. The mains cable must be easily accessible for disconnection.
  • No modification is allowed to the device, nor is it recommended to connect the device to any equipment or accessories not specified by the manufacturer, to ensure patient safety and security.
  • The device must have a backup source of electrical power to continue working in the event of a power loss and a power outage.
  • Do not use in a magnetic environment such as an MRI or X-ray, as this may cause the device to malfunction.
  • It is not recommended to use extension cords and adapters, as they are potential sources of sparks and fire.
  • Do not use acetone, solvents or any other flammable products to clean the device, and do not use abrasive powders.

Novo 10 liter oxygen generator malfunctions

In the following table, we discuss the most important malfunctions of the Novo 10L oxygen generator, the reasons that may lead to their occurrence, and how to deal with them:

holidaysthe reasonThe solution
The power button is pressed but the device does not turn on.The mains cable is not properly connected to the electrical outlet.Check the cable connection.
Voltage detection alarm tester does not work.Capacitor not charged, internal electrical fault.Check the circuit breaker at the front of the device, plug the device in for 10 minutes and retest, if the fault persists, contact an authorized service center.
The device is working and there is a flow but the green light is not lit.Pointer error.Contact an authorized service center.
The device is turned on but there is no streaming, the beep is constantly audible.Airway leakage, or other pressure problem.Turn off the device and contact the service center.
The device is working and there is a flow but there is a constantly audible beep.Internal electrical malfunction, or fault in the air circuit.Contact an authorized service center.
The machine stops in the middle of the session, then starts again a few minutes later.
  • Thermal safety device has been activated.
  • Filters are dirty.
  • Cooling fan is not working.
  • Turn off the device and wait for it to cool down.
  • Clean the filters and restart.
  • Contact the service center.
Disruption of oxygen flow at the outlet of the respirator.The tube is disconnected or the humidifier cap is loose.Make sure the tubes are connected well, and that the humidifier is tightly sealed.